103 Photos
Located
Charlotte, NC
Charlotte, NC
Usage
3,007 hrs
3,007 hrs
Serial number
DHKCEBBUCK0002682
DHKCEBBUCK0002682
Loading...
Protected by IronClad Assurance
This lot has been given an extensive inspection by an industry expert. If you find it's not as described, file a dispute and we'll make it right.
ID number
#15517579
In yard
No
Features
Air Conditioner, Straight Travel Pedal, Control Pattern Changer, Cab Screens, Rear & Side View Cameras, Tier 4, 2019 US EPA Label, Requires Diesel Exhaust Fluid, 11 ft 6 in Stick, Auxiliary Hydraulic Plumbing, 35.50 in Triple Grouser Track Shoes, Hydraulic Quick Coupler, 44 in Digging Bucket, Equipped w/Ryan's Attachment Controls. (Not functionally checked)


















Serial Number / VIN
DHKCEBBUCK0002682
Hour Meter / Odometer
3007 hrs-No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Paint
Scraps/scratches
Sheet Metal (fiberglass) Condition
Bent/damaged panels
Steps/Ladders
Right side body steps missing
Hand Rails
Bent/damaged
Glass
Front shattered
Exterior Lights
Operational; Right body light damaged


Travel Alarm
Operational
Horn
Operational
Seat Belts
Operational
Safety Lock Out/Stop
Operational
Swing Brake
Operational
Current Safety Manual
Current Operator/Maintenance Manual






















Seats/Armrests
Mirrors
Right side missing
Steering Controls
Hydraulic Controls
Auxiliary Hydraulic Control
Not functionally checked
Drivetrain Controls
Dash Console
Engine Oil Pressure
The fault indicator shuts off after the engine oil pressure rises.
Warning Lights
Operational; Maintenance/Service light stays on
Gauges
Operational
Air Conditioner
Operational
Heater
Operational
Limited Function Check
The main components are in place and operational as noted.












Engine
2019 US EPA Label, Requires Diesel Exhaust Fluid
Emission Label
A/C Compressor
Operational
Blow-by (subjective visual observation)
Minor
Starter
Operational
Exhaust System
Radiator
Oil Leaks
No dripping leaks
Fuel Leaks
No dripping leaks
Cooling System Leaks
No dripping leaks
Engine - Left Side
Engine - Right Side
DEF / AdBlue Tank
Limited Function Check
After jump starting, the engine ran.




Left Drive Motor
Right Drive Motor
Left Final Drive
Right Final Drive
Limited Function Check
The drivetrain was operational.














Pumps (Hydraulics)
Valves
Hydraulic Tank
Hydraulic Control Pattern Changer
Hoses (Hydraulics)
Loose mounts, braid exposed and bent hard lines
Auxiliary Hydraulic Plumbing
End of stick. Not operationally checked
Swing Motor
Hydraulic Center Swivel
Boom Lift Cylinder(s)
Stick Cylinder
Bucket Cylinder
Limited Function Check
The hydraulic system was operational.







Boom Condition
Stick Condition
Boom Base Pin and Bushings
Pin and Bushings Boom to Stick
Pins and Bushings Stick to Coupler
Heavy movement
Turntable Bearing
Bottom Covers
Limited Function Check
The main components were operational in a limited check.




















Left Roller Frame
Left Track Tensioner
Left Track Shoes
Left Grouser Height
25 mm
Left Track Links
Left Carrier Rollers
Left Track Rollers
Left Idler
Left Sprocket
Right Roller Frame
Right Track Tensioner
Right Track Shoes
Right Grouser Height
25 mm
Right Track Links
Right Carrier Rollers
Right Track Rollers
Right Idler
Right Sprocket




Excavator Bucket Condition
Cutting Edge / Teeth / Adapters
Quick Coupler
Not operational
Oil Sample Analysis
| engine | |
|---|---|
| date of analysis | Jul 08, 2026 |
| Silicon | 0 PPM |
| Tin | 0.88 PPM |
| Silver | 0 PPM |
| Aluminum | 0 PPM |
| Chromium | 0 PPM |
| Lead | 1.18 PPM |
| Copper | 2.56 PPM |
| Nickel | 0.18 PPM |
| Iron | 1.79 PPM |
| Glycol | NEG |
| Water | NEG |
| Fuel | <5% |
Items must be paid in full by Wednesday, January 8, 3000. Late fees will be applied after due date.
Get your equipment to where it needs to be with Ritchie Bros.' full-service door-to-door logistics and shipping solutions. We take care of every step of the journey with our all-inclusive service to get your equipment across borders, continents and oceans quickly and efficiently
The detailed equipment information is limited in scope, and Ritchie Bros. Auctioneers has not inspected any aspects or components of the equipment other than those expressly set forth herein. Unless expressly stated, we make no representations or warranties, express or implied, concerning the equipment or its components, including without limitation any representations or warranties concerning functionality, conformity or compliance with any safety standard or requirement of any applicable authority or regulatory body, fitness for any particular purpose, or merchantability. You are strongly advised to perform your own detailed inspection of the equipment prior to bidding.
Equipment is not tested under load or operated in all available gears. We make no representation or warranty that equipment is operating in accordance with manufacturers' specifications. No inspection has been performed with respect to any functionality aspect other than those expressly included herein. Only select photos have been provided for individual undercarriage components, and may not be indicative of the condition of the entire undercarriage as a whole.
Measurements are given as an estimate only. Actual loaded dimensions may vary based on truck/trailer height and the loaded machine configuration/position. It is the buyer's responsibility to measure all loads before leaving our auction site to ensure the load is safe for transport. All measurements should be verified by the buyer. Do not rely on these measurements for transportation purposes.