250 Photos
Located
Nisku, AB, CAN
Nisku, AB, CAN
Usage
361,724 km (224,765 mi)
361,724 km (224,765 mi)
Serial number
5KKPALCK78PZ10515
5KKPALCK78PZ10515
Loading...
A qualified Ritchie Bros. employee collected detailed equipment information and performed functional tests on the key components of this asset. You, or a proxy, may also inspect any items on site prior to bidding on auction day.
ID number
#14685374
In yard
Yes
Year
2008
Manufacturer
Model
Asset type
Serial number or VIN
5KKPALCK78PZ10515
Features
Detroit Series 60 6 Cylinder 14.0 L Diesel 515 hp Engine, 2007 US EPA Label, Engine Coolant Heater, Positive Air Shutoff, Webasto Engine Coolant Heater, Engine Brake, Eaton Fuller RTLO-16918B 18-Speed Manual Transmission, Double Differential Locks, 9072 kg Front Axle, 27033 kg Rears, Meritor RZ-166 R-SRS Drive Axles, 4.89:1 Axle Ratio, 36105 kg GVWR, Air Ride Cab, 34 in Mid Roof Sleeper Cab, Aluminum Wheels, 445/65R22.5 Front Tires, 11R24.5 Rear Tires, Dual Steering Boxes, Double Frame, Airliner Air Ride Suspension, 308 in Wheelbase, Dual PTO, Steel 12811 L Debris Tank, 407/412 Code, Hoist, Vibrator, Rear Hose Reel, Fresh Water Tank, Hydraulic Lift Tailgate, Manual Tailgate Locks, 8 in Suction Hose, Cat 3517 Hydraulic Driven Pump, Blower, Hotsy Boiler, Cordless Remote Control


























































Picture, Left Front Corner
Picture, Left Rear Corner
Picture, Right Rear Corner
Picture, Right Front Corner
Serial Number / VIN
5KKPALCK78PZ10515
Hour Meter / Odometer
361724 km-No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Indication of Additional Hours
There is an hour meter replacement/change label that has the following reading on it: reset at 361705 km
Paint
Sheet Metal (fiberglass) Condition
Steps/Ladders
Hand Rails
Glass
Exterior Lights
Some not operational, exterior work lights lights are not operational























Emissions Information
2007 US EPA Label
Emission Label
A/C Compressor
In place; ambient temperature too cold to check operation
Blow-by (subjective visual observation)
No noticeable vapor or pressure
Starter
Operational
Air Compressor
Operational
Fuel System
Operational
Exhaust System
Radiator
Engine - Left Side
Engine - Right Side
Limited Function Check
The engine started and ran.

































Engine Hours
Cannot confirm total hours
Mirrors
Window Controls
Left Manual / Right Power
Seats/armrests
Seat Belts
Operational
Steering Control
Horn
Air horn operational, Electric horn operational
Oil Pressure
The gauge registers in the operating range. 40 PSI
Warning Lights
Operational
Gauges
Operational
Gear Selector
Brake Control
Operational
Engine Brake
Operational
Clutch
Engages
PTO Control
Air engaged, Operational
ECM Miles
Unable to get ECM reading
Air Conditioner
The ambient temperature is too cold to check.
Heater
Operational
Limited Function Check
The main components are in place and operational as noted.































































Steering Components
Steer Axle
Transmission
Power Take Off
Operational
PTO Pump
Operational
Frame Condition
Front Drive Axle
Center Drive Axle
Rear Drive Axle
Limited Function Check
The drivetrain was operational without a load.
Cab Suspension Air Bags
Suspension Springs/Hangers
Suspension Bushings
Suspension Air Bags
Left Steer Tire
Left Front Drive Tires
Left Center Drive Tires
Left Rear Drive Tires
Right Rear Drive Tires
Right Center Drive Tires
Right Front Drive Tires
Right Steer Tire
Wheel Condition
Wheel Studs
Wet Kit Plumbing
Hydraulic Tank
Limited Function Check - Brakes
The service brakes are operational, The park brake is operational.









































































Vacuum Intake Hose
8 inches
Silencer
Oil Separator
Vacuum Pump
Vacuum Drive
PTO Driven
Pre Filter
Secondary Trap
Primary Trap
Debris Tank
Fully Opening Rear Door, Manual Door Locks
Water Tank
Boom Condition
Pressure Pump - Water
PTO Powered
Hose Reel
Wash Down System
Remote Control
Not operationally checked
Tool/Storage Boxes
Limited Function Check
The main chassis components functioned when checked without a load.
Oil Sample Analysis
| engine | |
|---|---|
| date of analysis | Feb 19, 2026 |
| Silicon | 0 PPM |
| Tin | 0.14 PPM |
| Silver | 0 PPM |
| Aluminum | 0.65 PPM |
| Chromium | 0.09 PPM |
| Lead | 4.08 PPM |
| Copper | 0.42 PPM |
| Nickel | 0 PPM |
| Iron | 8.25 PPM |
| Glycol | NEG |
| Water | NEG |
| Fuel | <5% |
Items must be paid in full by Friday, March 27, 2026. Late fees will be applied after due date.
Payment optionsSubmit your item to VeriTread and receive free, no-obligation freight quotes.
The detailed equipment information is limited in scope, and Ritchie Bros. Auctioneers has not inspected any aspects or components of the equipment other than those expressly set forth herein. Unless expressly stated, we make no representations or warranties, express or implied, concerning the equipment or its components, including without limitation any representations or warranties concerning functionality, conformity or compliance with any safety standard or requirement of any applicable authority or regulatory body, fitness for any particular purpose, or merchantability. You are strongly advised to perform your own detailed inspection of the equipment prior to bidding.
Equipment is not tested under load or operated in all available gears. We make no representation or warranty that equipment is operating in accordance with manufacturers' specifications. No inspection has been performed with respect to any functionality aspect other than those expressly included herein. Only select photos have been provided for individual undercarriage components, and may not be indicative of the condition of the entire undercarriage as a whole.
Measurements are given as an estimate only. Actual loaded dimensions may vary based on truck/trailer height and the loaded machine configuration/position. It is the buyer's responsibility to measure all loads before leaving our auction site to ensure the load is safe for transport. All measurements should be verified by the buyer. Do not rely on these measurements for transportation purposes.